IEC Elektriese
Nominale WS-spanning (50/60Hz) | 60V | 120V | 230V | 230V | ||
Maksimum Deurlopende Bedryfspanning (WS) | (LN) | Uc | 75V | 150V | 275V | 320V |
(N-PE) | Uc | 255V | 255V | 255V | 255V | |
Nominale ontladingsstroom (8/20μs) | (LN)/(N-PE) | In | 20 kA/25KA | |||
Maksimum ontladingsstroom (8/20μs) | (LN)/(N-PE) | lmaksimum | 50kA/50KA | |||
Impulsontladingsstroom (10/350μs) | (LN)/(N-PE) | limp | 12.5 kA/25KA | |||
Spesifieke Energie | (LN)/(N-PE) | W/R | 39 kJ/Ω/625KJ/Ω | |||
Aanklag | (LN)/(N-PE) | Q | 6As/12.5As | |||
Spanningsbeskermingsvlak | (LN)/(N-PE) | Up | 700V/1500V 1000V/1500V 1500 V/1500V 1600V/1500V/ | |||
Volg Huidige Onderbrekingsgradering | (N-PE) | I | 100ARMS | |||
Reaksietyd | (LN)/(N-PE) | tA | <25 ns/<100 ns | |||
Rugsteunsekering (maks.) | 315A/250A gG | |||||
Kortsluitstroomgradering (WS) | (LN) | lscCR | 25kA/50 kA | |||
TOV Weerstand 5s | (LN) | UT | 114V | 180V | 335V | 335V |
TOV 120 min | (LN) | UT | 114V | 230V | 440V | 440V |
Modus | Weerstaan | Veilige mislukking | Veilige mislukking | Veilige mislukking | ||
TOV Weerstand 200s | (N-PE) | UT | 1200V | |||
Aantal poorte | 1 |
UL Elektries
Maksimum Deurlopende Bedryfspanning (WS | (LN)/(N-PE) | MCOV | 75V/255V | 150V/255V | 275V/255V | 320V/255V |
Spanningsbeskermingsgradering | (LN)/(N-PE) | VPR | 330V/1200V | 600V/1200V | 900V/1200V | 1200V/1200V |
Nominale ontladingsstroom (8/20μs) | (LN)/(-PE) | In | 20KA/20KA | 20KA/20KA | 20KA/20KA | 20KA/20KA |
Kortsluitstroomgradering (WS) | (LN) | SCCR | 200KA | 150KA | 150KA | 150KA |
Meganies en Omgewingsvriendelik
Bedryfstemperatuurreeks | Ta | -40°F tot +158°F [-40°F]℃tot +70℃I |
Toelaatbare bedryfsvogtigheid | RH | 5%…95% |
Atmosferiese druk en hoogte | 80k Pa...106k Pa/-500m...2000m | |
Terminale Skroef Wringkrag | Mmax | 39.9 Ibf-in [4.5 Nm] |
Geleier Dwarssnit (maks) | 2AWG (Solied, Gestrand)/4AWG (Buigsaam) | |
35mm²(Solied, Gestrengeld)/25 mm²(Buigsaam) | ||
Montering | 35 mm DIN-rail. EN 60715 | |
Graad van Beskerming | IP 20 (ingebou) | |
Behuisingsmateriaal | Termoplasties: Blusgraad UL94V-0 | |
Termiese Beskerming | Ja | |
Bedryfstoestand/Foutaanduiding | Groen ok/Rooi defek | |
Afstandskontakte (RC) | Opsioneel | |
RC-skakelkapasiteit | WS: 250V /0.5 ABC: 250V/0.1 A: 125V/0.2 A; 75V/0.5A | |
RC-geleier-deursnee (maks.) | 16AWG (Solied)/1.5mm²(Verkoop) |
Bestellingsinligting
Bestelling Kode | 75 | 150 | 275 | 320 |
BY1-12.5-XXX/1+1 | 1207513 | 1215013 | 1227513 | 1232013 |
BY1-12.5-XXX/1S+1(metafgeleë kontakte) | 1207514 | 1215014 | 1227514 | 1232014 |
BY1-12.5-XXX/0 (spaarmodules) | 1207501 | 1215001 | 1227501 | 1232001 |
BY1-12.5-NPE/0 (spaarmodules) | 1205501 | 1255001 | 1225501 | 1225501 |
Legende
L-lyn
N Neutraal
PE Beskermende Aarde
S Seinkontakte Opsioneel
BY1-12.5-XXX/1(S)+1 | 150 | 275 | 320 | 385 |
Enkele Eenheid DIN 43880 Afmeting | 1 KTN | |||
Verpakkingsafmetings (H×B×L) | [200×230×330mm] | |||
Minimum bestelhoeveelheid | 32Eenhede |
BY1-12.5-XXX/0 | 150 | 275 | 320 | 385 |
BY1-12.5-NPE/0 | 25 | |||
Enkele Eenheid DIN 43880 Afmeting | 1 KTN | |||
Verpakkingsafmetings (H×B×L) | [200×230×330mm] | |||
Minimum bestelhoeveelheid | 64Eenhede |