IEC Elektriese
Nominale WS-spanning (50/60Hz) | UO/Un | 60V | 120V | 230V | 230V | 230V | 440V |
Maksimum Deurlopende Bedryfspanning (WS) | Uc | 75V | 150V | 275V | 320V | 385V | 440V |
Nominale ontladingsstroom (8/20μs) | In | 20KA | 20KA | 20KA | 20KA | 10KA | 10KA |
Maksimum ontladingsstroom (8/20μs) | Imaksimum | 50KA | 50KA | 50KA | 50KA | 50KA | 50KA |
Impulsontladingsstroom (10/350μs) | Iimp | 12.5KA | 12.5KA | 12.5KA | 12.5KA | 10KA | 10KA |
Spesifieke Energie | W/R | 39 kJ/Ω | 39 kJ/Ω | 39 kJ/Ω | 39 kJ/Ω | 25kJ/Ω | 25kJ/Ω |
Aanklag | Q | 6.25As | 6.25As | 6.25As | 6.25As | 5As | 5As |
Spanningsbeskermingsvlak | Up | 700V | 1000V | 1500V | 1600V | 1800V | 2000V |
Reaksietyd | tA | <25ns | |||||
Rugsteunsekering (maks.) | 315A/250A gG | ||||||
Kortsluitstroomgradering (WS) | ISCCR | 25KA/50KA | |||||
TOV Weerstaan 5s | UT | 114V | 180V | 335V | 335V | 335V | 580V |
TOV 120 min | UT | 180V | 230V | 440V | 440V | 440V | 765V |
Modus | Weerstaan | Veilige mislukking | Veilige mislukking | Veilige mislukking | Veilige mislukking | Veilige mislukking | |
Aantal poortes | 1 |
UL Elektries
Maksimum Deurlopende Bedryfspanning (WS | MCOV | 75V | 150V | 275V | 320V | 385V | 440V |
Spanningsbeskermingsgradering | VPR | 330V | 600V | 900V | 1200V | 1350V | 1500V |
Nominale ontladingsstroom (8/20μs) | I | 20KA | 20KA | 20KA | 20KA | 20KA | 20KA |
Kortsluitstroomgradering (WS) | SCCR | 100KA | 200KA | 150KA | 150KA | 150KA | 200KA |
Meganies en Omgewingsvriendelik
Bedryfstemperatuurreeks | Ta | -40°F tot +158°F [-40°F]℃tot +70℃I |
Toelaatbare bedryfsvogtigheid | RH | 5%…95% |
Atmosferiese druk en hoogte | 80k Pa...106k Pa/-500m...2000m | |
Terminale Skroef Wringkrag | Mmax | 39.9 Ibf-in [4.5 Nm] |
Geleier Dwarssnit (maks) | 2AWG (Solied, Gestrand)/4AWG (Buigsaam) | |
35mm²(Solied, Gestrengeld)/25 mm²(Buigsaam) | ||
Montering | 35 mm DIN-rail. EN 60715 | |
Graad van Beskerming | IP 20 (ingebou) | |
Behuisingsmateriaal | Termoplasties: Blusgraad UL94V-0 | |
Termiese Beskerming | Ja | |
Bedryfstoestand/Foutaanduiding | Groen ok/Rooi defek | |
Afstandskontakte (RC) | Opsioneel | |
RC-skakelkapasiteit | WS: 250V /0.5 ABC: 250V/0.1 A: 125V/0.2 A; 75V/0.5A | |
RC-geleier-deursnee (maks.) | 16AWG (Solied)/1.5mm²Verkoop) |
Bestellingsinligting
Bestelling Kode | 75 | 150 | 275 | 320 | 385 |
BY1-12.5-XXX/1 | 1207511 | 1215011 | 1227511 | 1232011 | 1238511 |
BY1-12.5-XXX/1S(metafgeleë kontakte) | 1207512 | 1215012 | 1227512 | 1232012 | 1238512 |
BY1-12.5-XXX/0 (spaarmodules) | 1207501 | 1215001 | 1227501 | 1232001 | 1238501 |
Legende
L-lyn
N Neutraal
PE Beskermende Aarde
S Seinkontakte Opsioneel
BY1-12.5-XXX/1(S) | 75 | 150 | 275 | 320 | 385 | 440 |
Enkele Eenheid DIN 43880 Afmeting | 1 KTN | |||||
Verpakkingsafmetings (H×B×L) | [200×230×330mm] | |||||
Minimum bestelhoeveelheid | 64Eenhede |
BY1-12.5-XXX/0 | 75 | 150 | 275 | 320 | 385 | 440 |
Enkele Eenheid DIN 43880 Afmeting | 1 KTN | |||||
Verpakkingsafmetings (H×B×L) | [200×230×330mm] | |||||
Minimum bestelhoeveelheid | 64Eenhede |