BY1-12.5-XXX/1(S) 75 150 275 320 385 440 | ||||||||
IEC Elektriese | ||||||||
Nominale WS-spanning (50/60Hz) | U₀/On | 60V | 120V | 230V | 230V | 230V | 400V | |
Maksimum Deurlopende Bedryfspanning (WS) | Ue | 75V | 150V | 275V | 320V | 385V | 440V | |
Nominale ontladingsstroom (8/20μs) | In | 20kA | 20kA | 20kA | 20kA | 10kA | 10kA | |
Maksimum ontladingsstroom (8/20μs) | lmaks | 50kA | 50kA | 50kA | 50kA | 50kA | 50kA | |
Impulsontladingsstroom (10/350μs) | slap | 12,5 kA | 12,5 kA | 12,5 kA | 12,5 kA | 10kA | 10kA | |
Spesifieke Energie | W/R | 39 kJ/Q | 39kJ/Ω | 39kJ/Ω | 39kJ/Ω | 25 kJ/Ω | 25kJ/Ω | |
Aanklag | Q | 6.25As | 6.25As | 6.25As | 6.25As | 5As | 5As | |
Spanningsbeskermingsvlak | Up | 700V | 1000V | 1500V | 1600V | 1800V | 2000V | |
Reaksietyd | tA | <25 ns | ||||||
Rugsteunsekering (maks.) | 315A/250AgG | |||||||
Kortsluitstroomgradering (WS) | lscCR | 25 kA/50 kA | ||||||
TOV Weerstand 5s | UT | 114V | 180 | 335V | 335V | 335V | 580V | |
UT | 180V | 230V | 440V | 440V | 440V | 765V | ||
TOV 120 min | Modus | Weerstaan | Veilige mislukking | Veilige mislukking | Veilige mislukking | Veilige mislukking | Veilige mislukking | |
Aantal poorte | 1 | |||||||
ULElectrical | ||||||||
Maksimum Deurlopende Bedryfspanning (WS) | MCOV | 75V | 150V | 275V | 320V | 385V | 440V | |
Spanningsbeskermingsgradering | VPR | 330V | 600V | 900V | 1200V | 1350V | 1500V | |
Nominale ontladingsstroom (8/20 μs) | Ek. | 20kA | 20kA | 20kA | 20kA | 20kA | 20kA | |
Kortsluitstroomgradering (WS) | sCCR | 100kA | 200kA | 150kA | 150kA | 150kA | 200kA | |
Meganies en Omgewingsvriendelik | ||||||||
Bedryfstemperatuurbereik Ta | -40°F tot +158°F [-40°F tot +70°F] | |||||||
Toelaatbare bedryfsvogtigheid RH | 5%…95% | |||||||
Atmosferiese druk en hoogte | 80k Pa…106k Pa/-500m..2000 m | |||||||
Terminale Skroef Wringkrag Mmax | 39.9 Ibf · duim [4.5 Nm] | |||||||
Geleier Dwarssnit (maks) | 2AWG (Solied, Gestrand)/4 AWG (Buigsaam) 35mm² (Solied, Gestrand)/25mm² (Buigsaam) | |||||||
Montering | 35mm DIN-rail, EN 60715 | |||||||
Graad van Beskerming | IP20 (ingebou) | |||||||
Behuisingsmateriaal | Termoplasties: Blusgraad UL94 V-0 | |||||||
Termiese Beskerming | Ja | |||||||
Bedryfstoestand/Foutaanduiding | Groen ok/Rooi defek | |||||||
Afstandskontakte (RC) | Opsioneel | |||||||
RC-skakelkapasiteit | AC:250V/0.5A;DC:250V/0.1A;125V/0.2A;75V/0.5A | |||||||
RC-geleier-deursnee (maks.) | 16AWG (Solied)/1.5mm² (Solied) |