Lugkompressor Spesiale TegnologieParameter En Modusse (WQC)
Tipe | Krag | Spanning | Gegradeerde stroom | Termiese relais-onderdeel aangepaste omvang |
WQC-12 | 0.75 kW | 380V | 2.1A | 1.7-2.5A |
WQC-12 | 1.1 kW | 380V | 2.5A | 2-3A |
WQC-12 | 1.5 kW | 380V | 3.6A | 2.8-4.4A |
WQC-12 | 2.2 kW | 380V | 5A | 4-6A |
WQC-12 | 3 kW | 380V | 6.6A | 5.2-8A |
WQC-32 | 4KW | 380V | 9A | 7-11A |
WQC-32 | 5.5 kW | 380V | 11A | 9-13A |
WQC-32 | 7.5 kW | 380V | 15A | 12-18A |
WQC-32 | 11 kW | 380V | 22A | 20-32A |
WQC-50 | 15 kW | 380V | 30A | 28-45A |
WQC-50 | 18.5 kW | 380V | 37A | 40-63A |
WQC-65 | 18.5 kW | 380V | 37A | 40-63A |
WQC-85 | 22 kW | 380V | 44A | 40-63A |
WQC-95 | 30 kW | 380V | 60A | 53-85A |
Tipe | Kontaktor | Standaard termiese relais | Beheermotorkrag (kW) | Gegradeerde stroom (A) | ||||
Tipe | Ingestelde stroom | 220V | 380V | 500V | 220V | 380V | ||
QCX5-9 | CJX5-9 | JRS-5-12/Z | 3.6A | 0.75 | 1.5 | 2.2 | 11 | 9 |
QCX5-9 | CJX5-9 | JRS-5-12/Z | 5A | 1.1 | 2.2 | 3 | 11 | 9 |
QCX5-9 | CJX5-9 | JRS-5-12/Z | 6.6A | 1.5 | 3 | 3.7 | 11 | 9 |
QCX5-9 | CJX5-9 | JRS-5-12/Z | 9A | 2.2 | 4 | 5.5 | 11 | 9 |
QCX5-12 | CJX5-12 | JRS-5-12/Z | 3.6A | 0.75 | 1.5 | 2.2 | 13 | 12 |
QCX5-12 | CJX5-12 | JRS-5-12/Z | 5A | 1.1 | 2.2 | 3 | 13 | 12 |
QCX5-12 | CJX5-12 | JRS-5-12/Z | 6.6A | 1.5 | 3 | 3.7 | 13 | 12 |
QCX5-12 | CJX5-12 | JRS-5-12/Z | 9A | 2.2 | 4 | 5.5 | 13 | 12 |
QCX5-12 | CJX5-12 | JRS-5-12/Z | 11A | 3 | 5.5 | 7.5 | 13 | 12 |
QCX5-22/11 | CJX5-22/11 | JRS-5-20/F | 11A | 3 | 5.5 | 7.5 | 22 | 22 |
QCX5-22/11 | CJX5-22/11 | JRS-5-20/F | 15A | 3.7 | 7.5 | 9 | 22 | 22 |
QCX5-22/22 | CJX5-22/22 | JRS-5-20/F | 11A | 3 | 5.5 | 7.5 | 22 | 22 |
QCX5-22/22 | CJX5-22/22 | JRS-5-20/F | 15A | 3.7 | 7.5 | 9 | 22 | 22 |
QCX5-32 | CJX5-32 | JRS-5-20/F | 19A | 5.5 | 11 | 11 | 30 | 30 |
QCX5-32 | CJX5-32 | JRS-5-20/F | 22A | 5.5 | 11 | 11 | 30 | 30 |
QCX5-40 | CJX5-40 | JRS-5-20/F | 19A | 5.5 | 11 | 11 | 40 | 40 |
QCX5-40 | CJX5-40 | JRS-5-20/F | 22A | 5.5 | 11 | 11 | 40 | 40 |
QCX5-40 | CJX5-40 | JRS-5-20/F | 29A | 7.5 | 15 | 18.5 | 40 | 40 |
QCX5-40 | CJX5-40 | JRS-5-20/F | 35A | 9 | 18.5 | 22 | 40 | 40 |
Dimensie en Montering Dimensie
■ Die aansitter kan langdurig en sonder termiese relais werk. Die frekwensie kan 600 keer/uur in kort tyd wees en herhaaldelik werk;
■ Die aantrekkingsspoel kan betroubaar werk wanneer die nominale spanning 85%~105% is, die vrygestelde spanning is ongeveer 40~55% van die nominale spanning;
■ Die aansitterkontak in die bedryfsfrekwensie is 600/uur, die sirkelvormige telegram bly lei vir die meriete van 40%. Die nominale stroom word deurgevoer, wanneer die skeiding plaasvind, is die faktor 0.35, die elektriese lewensduur daarvan is nie laer as 640 000 keer nie;
■ Die aansitter se meganiese lewensduur is 3 miljoen keer;
■ Die aansitter se hulpkontak, die nominale stroom daarvan is 5A;
■ Die termiese relais het die temperatuurkompensasie-organisasie, wat die temperatuur kan balanseer wat veroorsaak word deur die veranderinge in die spanning rondom temperatuur;
■ Die termiese relaisoorlading is volgens die bepalings. Sien die volgende.