Produk Eienskappe
Ultradun ontwerp: breedte 18 mm (1SU) / 36 mm (2SU)
Internasionale universele invoer: 85-264VAC (277VAC beskikbaar)
Geen-las verlies: <0.3W
Isolasievlak: II
Slaag LPS (Beperkte Kragtoevoer)
Verstelbare GS-uitsetspanning
Natuurlike lugverkoeling (werkstemperatuur: -30℃~ +70℃)
Kan op 35/7.5 of 35/15 spoor geïnstalleer word
Oor spanningsvlak: Ⅲ
LED dui aan dat die krag aan is
Tegniese Data | HW4111805 | HW4111812 | HW4111815 | HW4111824 | HW4111848 | |
Uitset | GS-spanning | 5V | 12V | 15V | 24V | 48V |
Gegradeerde stroom | 2.4A | 1.25A | 1A | 0.63A | 0.32A | |
Gegradeerde krag | 12W | 15W | 15W | 15.2W | 15.4W | |
Rimpeling en geraas (maks) | 80mVp-p | 120mVp-p | 120mVp-p | 150mVp-p | 240mVp-p | |
Spanningsaanpassingsbereik | 4.5-5.5V | 10.8-13.8V | 13.5-18V | 21.6-29V | 43.2-55.2V | |
Spanningsakkuraatheid | ±2.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | |
Lineêre Aanpassingskoers | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | |
Laai Aanpassingstempo | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | |
Begin- en Opstaantyd | 2000ms, 80ms/230VAC 2000ms, 80ms/115VAC (Onder Volle Las) | |||||
Houtyd | 300ms/230VAC 12ms/115VAC (Onder volle las) | |||||
Invoer | Spanningsbereik | 85-264VAC (277VAC beskikbaar) 120-370VDC (390VDC beskikbaar) | ||||
Frekwensiebereik | 47-63Hz | |||||
Doeltreffendheid | 80% | 85% | 85.5% | 86% | 87% | |
Wisselstroom | 0.5A/115VAC 0.25A/230VAC | |||||
Stroomstootstroom | Koue begin 25A/115VAC 45A/230VAC | |||||
Beskerming | Oorlading | 110-145% van die gegradeerde uitsetkrag | ||||
Wanneer die uitsetspanning minder as 50% is, is dit in hikmodus, en dit kan outomaties herstel nadat die abnormale lastoestand verwyder is.Wanneer die uitsetspanning 50%~100% is, is dit in konstante stroommodus, en dit kan outomaties herstel nadat die abnormale lastoestand verwyder is. | ||||||
Oorspanning | 5.75-6.75V | 14.2-16.2V | 18.8-22.5V | 30-36V | 56.5-64.8V | |
Beskermingsmodus: Skakel die uitset af, klem deur die diode | ||||||
Afmetings: in (mm) | Bedradingsdiagramme | |||||
| |
Tegniese Data | HW4113605 | HW4113612 | HW4113615 | HW4113624 | HW4113648 | |
Uitset | GS-spanning | 5V | 12V | 15V | 24V | 48V |
Gegradeerde stroom | 3A | 2A | 2A | 1.5A | 0.75A | |
Gegradeerde krag | 15W | 24W | 30W | 36W | 36W | |
Rimpeling en geraas (maks) | 80mVp-p | 120mVp-p | 120mVp-p | 150mVp-p | 240mVp-p | |
Spanningsaanpassingsbereik | 4.5-5.5V | 10.8-13.8V | 13.5-18V | 21.6-29V | 43.2-55.2V | |
Spanningsakkuraatheid | ±2.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | |
Lineêre Aanpassingskoers | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | |
Laai Aanpassingstempo | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | |
Begin- en Opstaantyd | 2000ms, 80ms/230VAC 2000ms, 80ms/115VAC (Onder Volle Las) | |||||
Houtyd | 300ms/230VAC 12ms/115VAC (Onder volle las) | |||||
Invoer | Spanningsbereik | 85-264VAC (277VAC beskikbaar) 120-370VDC (390VDC beskikbaar) | ||||
Frekwensiebereik | 47-63Hz | |||||
Doeltreffendheid | 82% | 88% | 89% | 89% | 90% | |
Wisselstroom | 0.5A/115VAC 0.25A/230VAC | |||||
Stroomstootstroom | Koue begin 25A/115VAC 45A/230VAC | |||||
Beskerming | Oorlading | 110-145% van die gegradeerde uitsetkrag | ||||
Wanneer die uitsetspanning minder as 50% is, is dit in hikmodus, en dit kan outomaties herstel nadat die abnormale lastoestand verwyder is.Wanneer die uitsetspanning 50%~100% is, is dit in konstante stroommodus, en dit kan outomaties herstel nadat die abnormale lastoestand verwyder is. | ||||||
Oorspanning | 5.75-7.5V | 15-18V | 18.8-22.5V | 30-36V | 56.5-64.8V | |
Beskermingsmodus: Skakel die uitset af, klem deur die diode | ||||||
Afmetings: in (mm) | Bedradingsdiagramme | |||||
| |